On this page
- What is CPCB lab recognition?
- Does CPCB or MoEF&CC recognise environmental labs?
- What do the CPCB guidelines for environmental laboratories require?
- Which parameters must be NABL accredited for CPCB recognition?
- What documents does the CPCB application need?
- How much does CPCB lab recognition cost?
- How do you apply on the CPCB EPA lab portal?
- How long is CPCB recognition valid, and how is it renewed?
- What PT and AQC must a recognised lab take part in?
- What does a CPCB surprise inspection check?
- How do environmental labs lose time and money on recognition?
- Where is the list of CPCB approved laboratories in India?
- What do the Environment Audit Rules 2025 mean for recognised labs?
- Where Tanush LIMS fits
- Frequently asked questions
- Sources
To get CPCB lab recognition, an environmental laboratory needs NABL accreditation (ISO/IEC 17025:2017) for CPCB's criteria parameters, ISO 45001:2018 certification, at least 150 square metres of working area and at least nine staff. It applies online on CPCB's EPA lab portal and pays ₹50,000 plus GST. CPCB scrutinises the application, issues a recognition certificate and notifies the lab and its Government Analysts in the Gazette. Recognition lasts three years. Since June 2021, CPCB, not MoEF&CC, recognises private labs under the Environment (Protection) Act, 1986.
This guide follows the official texts: MoEF&CC notification S.O. 2340(E) of 16 June 2021, its amendment S.O. 2409(E) of 19 June 2024, CPCB's Guidelines for Recognition of Environmental Laboratories (LATS/9/2024-2025, Revised & Updated Version, December 2024, posted on CPCB's website in June 2025) and CPCB's notice of 10 April 2026 on mandatory parameters. CPCB issues new notices often, so check the EPA lab portal before you apply.
What is CPCB lab recognition?
CPCB lab recognition is recognition of a laboratory as an "environmental laboratory" under section 12(1)(b) of the Environment (Protection) Act, 1986. Under section 13, its senior analysts can also be recognised as Government Analysts for samples of water, air, soil or other substances. CPCB now uses both powers on behalf of the Central Government.
Three things make recognition worth having, according to CPCB's guidelines:
- Evidence in court. A report signed by the Government Analyst may be used as evidence of facts in a court of law under section 14 of the Act (Annexure X, term 10).
- SPCB empanelment. CPCB notes that some SPCBs and PCCs require EPA recognition before they empanel a lab under the Water and Air Acts (para 1.5).
- All-India jurisdiction. A recognised lab can work as an environmental laboratory in any state (para 2.23).
NABL accreditation is not a substitute for recognition. It is a precondition for it. For the NABL side, see how to get NABL accreditation.
Does CPCB or MoEF&CC recognise environmental labs?
CPCB does, for private and government labs alike. People still search for "MoEF recognised laboratory" because the ministry (MoEF, now MoEF&CC) recognised private labs itself until 2021.
| Notification | What it did |
|---|---|
| S.O. 145(E), 21 February 1991 | Delegated recognition of labs and Government Analysts to CPCB, but kept private labs with the Central Government |
| S.O. 2340(E), 16 June 2021 | Superseded S.O. 145(E). Recognition of private labs and their Government Analysts "shall be done by the Central Pollution Control Board". Required NABL accreditation for all criteria parameters, plus ISO 45001, before applying |
| S.O. 2409(E), 19 June 2024 | Extended paragraph 1 to "laboratories or institutes as environmental laboratories", set recognition at three years and rewrote the proficiency testing clause |
MoEF&CC still has a role. Its officers sit on the joint surprise-inspection team with CPCB and the State Board (S.O. 2340(E), para 8) and on CPCB's expert committee (guidelines, para 2.19). MoEF&CC's environmental labs page still lists recognition notifications from 2012 to 2018. For who holds valid recognition today, use CPCB's lists, covered further down.
What do the CPCB guidelines for environmental laboratories require?
The guidelines set six prerequisites (para 2.9). The portal does not let you move to the next step until you meet all of them:
- a registered legal entity (company, society, trust, partnership or LLP, or a government notification);
- premises in a designated authorised area, shown by a document from the Registrar of Firms, the Directorate of Industries or an Industries Centre, the municipal or local body, MSME or the Pollution Control Board;
- valid ISO/IEC 17025:2017 accreditation from NABL;
- valid ISO 45001:2018 certification;
- at least nine staff;
- at least 150 m² of working area, not counting administration and accounts.
The guidelines say an application without NABL accreditation and ISO 45001 certification "will be summarily rejected" (para 2.10.3).
How much space does the lab need?
Table 2.1 of the guidelines splits the 150 m² minimum by section. Individual sections may differ, but the total may not fall below 150 m², and you upload a layout plan with dimensions.
| Laboratory section | Minimum space |
|---|---|
| Water, wastewater, and soil, sediment, sludge and hazardous waste analysis | 60 m² |
| Microbiological and biological analysis | 15 m² |
| Ambient air and source emission | 25 m² |
| Instrumentation (common and sophisticated instruments) | 30 m² |
| Sampling equipment, storage including compressed gas, library, committee room and staff area | 20 m² |
| Total | 150 m² |
What staff does the lab need?
Table 2.2 gives an indicative list of nine positions. Each post can be filled by an "equivalent".
| Position | Qualification | Experience |
|---|---|---|
| Head of laboratory | Ph.D., M.Sc. or M.Tech. | More than 10 years |
| Environmental scientist | Ph.D., M.Sc. or B.Tech. | More than 5 years |
| Junior scientist (chemical) | M.Sc. in chemistry or environmental science | More than 3 years |
| Junior scientist (microbiology) | M.Sc. in microbiology or environmental science | More than 3 years |
| Technical officer or assistant | M.Sc., B.E., B.Tech. or diploma in engineering | More than 3 years |
| Laboratory analyst | M.Sc. or B.Sc. | More than 2 years |
| Laboratory or field assistant | B.Sc. in chemistry, zoology or botany | More than 2 years |
| Laboratory attendant or multitasking staff | 12th or matriculation | Not specified |
| Administration or accounts | B.Com., B.A. or B.Sc. | More than 2 years |
Who can be a Government Analyst?
A private lab nominates up to three senior analysts (para 2.10.25). Under rule 10 of the Environment (Protection) Rules, 1986, each must be:
- a science graduate with five years' experience in a lab doing environmental investigation, testing or analysis; or
- a science post-graduate, or a graduate in engineering or medicine, with two years' such experience; or
- a post-graduate in environmental science with two years' such experience.
The guidelines add an age limit: the nominee must not have reached 65 or the retirement age, whichever is lower (para 2.10.24). Reports are signed by the analyst and the supervising analyst, and countersigned by a Government Analyst or a NABL authorised signatory (para 2.10.29).
What else must the lab show?
- Biometric attendance at the lab entrance for all staff and Government Analysts. Para 2.10.31 asks for the past two months of records, and the checklist asks for three, so keep at least three.
- Geo-tagging. Pin the lab's location on the portal map (para 2.10.12).
- Photographs of each section, from the front elevation to waste collection and gas storage (para 2.10.13). CPCB's notice of 8 December 2023 says the geo-tag must be visible on every image.
- A video with geo-tags, no longer than two minutes, shared as a Google Drive link (para 2.10.14).
- Undertakings on the code of ethics (Annexure I) and the terms and conditions of recognition (Annexure X).
Which parameters must be NABL accredited for CPCB recognition?
CPCB's notice of 10 April 2026 sets the current rule:
- Labs applying from April 2026 need NABL accreditation for all 36 criteria parameters.
- The "additional mandatory" parameters must be accredited within a year. The notice says there will be no relaxation after 31 March 2027.
- Any other parameter you want recognised must already be in your NABL scope when you apply, fresh or renewal.
- Pesticides were dropped from the organics group, and benzo(a)pyrene and mixing height from the air group, as criteria mandatory parameters.
| Group | The 36 criteria parameters |
|---|---|
| Water and wastewater: physical (5) | Conductivity, pH, total dissolved solids, total suspended solids, turbidity |
| General inorganic (9) | Alkalinity, ammoniacal nitrogen, chloride, fluoride, total hardness, nitrate nitrogen, nitrite nitrogen, phosphate, sulphate |
| Trace metals (13) | Arsenic, boron, cadmium, total chromium, hexavalent chromium, copper, iron, lead, mercury, nickel, potassium, sodium, zinc |
| Organics (2) | BOD, COD |
| Microbiology (2) | Total coliform, faecal coliform |
| Ambient air (2) | Nitrogen dioxide, sulphur dioxide |
| Stack emission (3) | Particulate matter, sulphur dioxide, oxides of nitrogen |
The additional mandatory list adds parameters in every group: for example cyanide, dissolved oxygen, oil and grease, E. coli and a fish bioassay for water; PM10, PM2.5, ozone and benzene for ambient air; and soil, hazardous waste, noise and meteorological parameters.
Para 2.10.15 of the guidelines adds that recognition is granted only for parameters covered by your NABL scope. The notice also says the portal is still being updated. If a parameter does not appear on it, send the list to CPCB at epa.cpcb@gov.in in the format attached to the notice.
For the methods behind the air and stack parameters, see our guides to ambient air quality monitoring and stack emission monitoring.
What documents does the CPCB application need?
Section 2.11 of the guidelines is a 34-item checklist. The table groups it by where the papers usually come from. The instruction sheet on the portal asks for every upload as a PDF of no more than 2 MB.
| Area | What to upload |
|---|---|
| Legal and location | Registration or incorporation certificate, GST and PAN, the lab's location in an authorised area on Google Maps |
| Premises | Covered area and section dimensions, layout map, photographs including the front of the building, video link |
| People | Organisation chart, senior management, staff list with qualifications, designation, experience, duties and pay, biometric attendance for three months, work allotment, training records |
| Instruments | Lists of sampling, sample-processing and analytical instruments with purchase dates, calibration status with validity, maintenance and service contracts |
| Methods and quality control | Parameters analysed with method, range and detection limit; reference materials and CRMs with expiry dates; intra-lab QC records; external PT and AQC records for three years; your last three CPCB AQC results |
| Accreditation | NABL certificate and scope with the mandatory parameters highlighted; ISO 45001 certificate with validity |
| Undertakings | Code of ethics, acceptance of terms by the head of the lab, up to three Government Analyst nominations with bio-data and their own acceptance of terms |
| Other | Write-up or SOP on lab waste, water supply and distilled water, grades of glassware and chemicals, your schedule of analysis charges |
The checklist asks for the NABL certificate "with accepted validity at least 1½ years prior from the expiry date". Read plainly, that means at least 18 months of accreditation left, so check with CPCB before applying if your NABL renewal is close.
How much does CPCB lab recognition cost?
The fees are in para 2.3 of the guidelines, and the AQC fee is in Annexure IX and CPCB's AQC notices.
| Fee | Amount |
|---|---|
| Fresh application: first time, after recognition has expired, or after a change of lab name or address | ₹50,000 + GST as applicable |
| Renewal, or a change of Government Analysts | ₹25,000 + GST as applicable |
| Refund if rejected for not meeting a mandatory requirement | 50% of the fee |
| CPCB AQC participation, private labs | ₹30,000 a year |
| CPCB AQC participation, government, PSU and autonomous labs | ₹20,000 a year |
Application fees are paid through the portal's payment gateway. CPCB's notice for the 39th AQC exercise (2 September 2026) shows GST as exempted on the AQC fee, citing an advance ruling.
A worked example
Over one three-year recognition, a private lab pays CPCB ₹50,000 plus GST to apply and ₹30,000 a year for AQC. That is ₹1,40,000, plus GST on the application fee. A renewal with no changes then costs ₹25,000 plus GST. NABL fees, ISO 45001 certification, PT schemes, calibration and staff are all extra.
Can a recognised lab charge what it likes?
No. The terms of recognition say a lab "shall charge rates not exceeding those fixed by Central Pollution Control Board" in its schedule of analysis charges, notified on 23 February 2022 (Annexure X, term 6). For example, that schedule lists ₹1,500 for BOD and ₹850 for COD in water and wastewater, with GST extra. Term 7 adds that the lab shall not charge rates higher than those it charges any other government or public sector organisation.
How do you apply on the CPCB EPA lab portal?
Apply on the EPA lab portal at epalab.cpcb.gov.in, which CPCB's April 2026 notice names as its revised portal. The guidelines still print an older address. Para 2.4 sets six steps:
- Register the lab's name, address and contact details. Login details are verified by OTP.
- Choose the type of application: new, renewal or other.
- Fill the prerequisites. If any is missing, the system will not accept the application.
- Fill the lab details: scope, quality control activities, the video and photographs with GPS location.
- Upload the supporting documents.
- Self-check against the checklist, pay the fee online and submit.
CPCB then works through the application (paras 2.14 to 2.20):
- Its team scrutinises the application and verifies the documents. The status shows on the portal.
- Minor deficiencies are sent back to you with a time limit. If you miss it, you apply afresh.
- Major shortcomings, or a missing prerequisite, lead to rejection with a 50% refund.
- The competent authority of CPCB approves the application.
- CPCB issues the recognition certificate, notifies the lab and its Government Analysts in the Gazette, and adds the lab to its list.
Para 2.21 says approval takes a maximum of one month after a complete application is received.
Some changes need a new application. If the lab changes its name or premises, it applies afresh at the fresh fee. To add or replace a Government Analyst, it applies as a renewal (portal instruction sheet).
How long is CPCB recognition valid, and how is it renewed?
CPCB recognition is valid for three years. S.O. 2409(E) replaced the 2021 rule, which ended recognition with the NABL or ISO 45001 validity, with a flat three years. The lab must hold valid NABL accreditation and ISO 45001 certification throughout (guidelines, paras 2.1 and 2.5). The portal's older FAQ still describes the 2021 rule, so go by the notification.
- When to apply: at least one month before expiry (para 2.8 and the April 2026 notice). An application after expiry is treated as a fresh one, at the fresh fee.
- What counts as a renewal: only if the lab's name and premises, scope, Government Analysts and instruments are unchanged, with an undertaking saying so. You submit renewed NABL and ISO 45001 certificates and updated CRM, staff and calibration details (para 2.7). Any change means a full fresh application.
- How to describe it: a recognised lab may print "Recognized under The Environment (Protection) Act, 1986" on reports, stationery and signboards, with the validity period (para 2.22). The claim must stop when recognition expires (Annexure X, term 18).
What PT and AQC must a recognised lab take part in?
S.O. 2409(E) requires a recognised lab to take part in every inter-laboratory comparison CPCB conducts, and in a proficiency testing programme by a provider certified under ISO/IEC 17043. Together they must cover all parameters under recognition within two years of recognition. The lab pays the fees, and CPCB puts the results in the public domain.
The guidelines add the pass marks:
- a z-score below 2.0 for every parameter, with a repeat PT for any that miss (para 2.10.21);
- CPCB AQC performance of at least 70% during recognition (para 2.10.22);
- if performance was unsatisfactory in two of the last three AQC rounds, a root cause analysis and a satisfactory result in another PT or ILC, as NABL 163 requires (para 2.10.22).
CPCB's five-year AQC plan rotates the matrix each year:
| Round | Year | Parameters |
|---|---|---|
| 37th | 2024-25 | General physico-chemical (set A), heavy metals, soil |
| 38th | 2025-26 | Biological parameters |
| 39th | 2026-27 | General physico-chemical (set B), heavy metals, soil |
| 40th | 2027-28 | Pesticides (OCPs and OPPs) |
| 41st | 2028-29 | Air parameters |
The 39th round sends fresh water samples for pH, conductivity, alkalinity, fluoride, phosphate, nitrate, sulphate, hardness, calcium, magnesium, TDS, TSS, COD, BOD and ten metals (notice of 2 September 2026). For the two oxygen demand tests, see BOD and COD test methods.
What does a CPCB surprise inspection check?
A joint team of MoEF&CC, CPCB and the State Board, with at least two or three experienced officers, can inspect the lab at any time, physically or virtually (S.O. 2340(E), para 8; guidelines, paras 2.24 and 2.25). CPCB publishes the inspection reports on the EPA lab portal.
The published reports follow a standard format. Apart from checking the documents in the application, inspectors look at:
- "records, registers, calculations and test results in respect of tests conducted";
- calibration records, stock registers for chemicals and CRMs, and purchase bills for instruments;
- biometric attendance for the past three months;
- the number of samples tested in each matrix, with parameters, for the past three years;
- the layout plan, balance checks, distilled water quality checks and safety provisions.
Findings in the published reports include parameters in the recognition that were not in the NABL scope, a working area below 150 m², training records not kept up to date, and instrument log books with no analyst name or operating time.
Para 2.26 lists the action for each kind of shortcoming. A selection:
| Shortcoming | Action |
|---|---|
| A prerequisite not met | Recognition revoked; apply afresh |
| Method not standard or validated | Recognition cancelled for that parameter |
| No valid CRM | Analysis of that parameter stopped until a valid CRM is bought |
| Calibration certificate out of date | Analysis stopped until a valid certificate is submitted |
| No PT for mandatory parameters | Recognition suspended |
| Missed at least two of the last three CPCB AQC rounds | Recognition suspended |
| Photographs not matching the actual location | Suspended for at least three months |
| A complaint verified as correct | Recognition cancelled for three months |
Between inspections, the lab reports to CPCB. S.O. 2340(E) asks for a compliance report on the portal twice a year, and CPCB's April 2026 notice asks recognised labs to submit their quarterly report there. The quarterly proforma asks, month by month, for the number of samples and parameters analysed in fresh water, wastewater, soil, ambient air, noise and source emissions.
How do environmental labs lose time and money on recognition?
Most of the costly problems here are not about chemistry. They are about dates, scope and records.
A missed renewal date. Apply after expiry and you pay the fresh fee of ₹50,000 instead of ₹25,000, plus GST, and the lab cannot claim recognition while the new application is processed.
A gap between the NABL scope and the CPCB scope. Recognition covers only accredited parameters, and the additional mandatory parameters must be accredited by 31 March 2027. A parameter that drops out of the NABL scope puts its CPCB recognition at risk too, and inspection teams compare the two lists.
Records that only one person can find. Published inspection reports record stock registers and purchase bills that could not be shown because "the concerned person was not available". Each gap becomes a query, and each query delays the report.
Counting by hand. The quarterly report needs monthly sample and parameter counts by matrix, and an inspection asks for three years of them. If the counts come from paper registers, someone rebuilds them every quarter.
Typing the same data again. Every renewal asks again for CRMs, staff and calibration details. Labs that keep these in scattered spreadsheets rebuild them each time. Our guide to the hidden cost of Excel in labs covers the wider pattern.
None of this needs a compliance system. It needs the daily work recorded once, in one place, so the answer exists when someone asks.
Where is the list of CPCB approved laboratories in India?
CPCB publishes two state-wise PDF lists of labs with valid recognition on its Recognition of Labs (EP Act) page:
- Private labs. The current list is dated 24 July 2026 and has 207 entries.
- Government, semi-government, PSU and educational institute labs. The current list is dated 31 May 2026.
Each entry gives the lab's address, its Government Analysts, the groups of parameters it is recognised for, the Gazette notification or recognition letter, and the validity date. The EPA lab portal's home page also shows recognised labs on a map.
When you check a lab, look at the validity date and the groups of parameters. A lab recognised for water and wastewater groups is not thereby recognised for stack emission or hazardous waste.
What do the Environment Audit Rules 2025 mean for recognised labs?
MoEF&CC notified the Environment Audit Rules, 2025 as S.O. 3973(E) on 29 August 2025. Registered Environment Auditors (REAs) carry out environment audits. Their duties include "conducting sampling and analysis of emissions, effluents, wastes" (rule 3), and they may enter premises and collect samples on assignments from government bodies (rule 4). The National Productivity Council signed on as the Environment Audit Designated Agency, PIB reported on 20 March 2026.
The labs come in through the auditors' eligibility. MoEF&CC's guidelines for certifying and registering auditors for environmental clearance and CRZ audits, posted on 30 September 2026, say an REA must have lab support for sampling and analysis. That support can be in-house, or "an external laboratory recognised by MoEF&CC under section 12 of the Environment (Protection) Act, 1986", or one recognised by the State Board or PCC, or one accredited by NABL, "as applicable" (para 7.1). Firms registering as REAs need the same (para 8.1).
So E(P) Act recognition is one of three routes a lab can offer an auditor, alongside SPCB recognition and NABL accreditation. Keep your Gazette notification, scope and validity date ready to show.
Where Tanush LIMS fits
CPCB recognises laboratories, not software, and no software makes a lab recognised. What the joint inspection team asks for is records: the calculations and results for each test, calibration records, and how many samples of each matrix you tested. Tanush LIMS keeps the technical side of those records as the work happens.
- Methods and limits. The library includes water, wastewater, ambient air, stack emission, noise and soil methods, with E(P) Rules Schedule VI and NAAQS 2009 among its built-in standards. Standards load as drafts that your lab reviews and activates. Tests outside the library, such as TCLP for hazardous waste or meteorological monitoring, are set up for your lab during setup.
- Your NABL scope. Tanush sets the software up to your scope. You can import it from Excel and mark which parameters are accredited.
- Inward and site work. Sample codes are created at inward, along with who drew the sample and any readings measured at site.
- Worksheets. In Formula mode, analysts enter readings and results calculate. AAS and ICP export files can be imported on metals worksheets.
- Locked results and history. Once a sample is approved, its results are locked. A correction means sending the test back, and every earlier run stays in the run history. An audit log records changes, with old and new values.
- Instruments. The equipment register holds calibration due dates and history, and instruments past their due date are greyed out on the worksheet.
- Reports. Stack emission and noise layouts sit alongside the standard report.
A CPCB quarterly report format can be built for your lab during setup. ISO 45001, biometric attendance and geo-tagged photographs stay outside the LIMS. It runs on a PC in your lab, even without internet, or in the cloud. See Tanush LIMS for water testing labs and for air, stack and noise monitoring, or book a demo.
Frequently asked questions
Is NABL accreditation enough without CPCB recognition?
For many customers, yes. Some environmental clearance conditions accept either: an Expert Appraisal Committee meeting of February 2023 asked for monitoring "through laboratories recognized under Environment (Protection) Act, 1986 or NABL accredited laboratories". But only recognition gives you Government Analysts whose reports can be used as evidence under section 14, and some SPCBs require it for empanelment. Read each consent or clearance condition.
Can a lab with ISO 9001 instead of NABL accreditation be recognised?
No. S.O. 2340(E) requires NABL accreditation for all criteria parameters, plus ISO 45001, before applying. CPCB's protocol on the portal says fresh applications based on ISO 9001 with ISO 45001 or OHSAS 18001 are no longer accepted, and ISO 9001-based renewals were considered only up to 31 December 2022.
How long does CPCB take to approve an application?
The guidelines give a maximum of one month after a complete application with all documents is received (para 2.21). Any time spent answering CPCB's queries comes on top, so apply well before you need the recognition.
Can a CPCB-recognised lab take samples in other states?
Yes. Para 2.23 says a recognised lab has jurisdiction to work as an environmental laboratory in any state. It must follow standard sampling, preservation and transport protocols.
What happens if our Government Analyst leaves?
Their recognition ends when they leave the lab (Annexure XI, term 2). The head of the lab must tell CPCB within fifteen days and start filling the vacancy (Annexure X, term 9). The guidelines ask you to apply for a replacement at least one month before the analyst leaves. A change of Government Analysts is filed as a renewal, at ₹25,000 plus GST.
Where do I find the old MoEF approved laboratory list?
MoEF&CC's environmental labs page still holds notifications from 2012 to 2018, when the ministry recognised private labs. They are historical. CPCB's current lists of private and government labs show who holds valid recognition today.
Sources
- MoEF&CC, S.O. 2340(E), 16 June 2021: delegation of recognition of environmental laboratories to CPCB, Gazette of India, Extraordinary
- MoEF&CC, S.O. 2409(E), 19 June 2024: amendment to S.O. 2340(E), Gazette of India, Extraordinary
- CPCB, Guidelines for Recognition of Environmental Laboratories under the Environment (Protection) Act, 1986, LATS/9/2024-2025, Revised & Updated Version, December 2024 (paras 1.4, 1.5, 2.1 to 2.28; Annexures I, III, IX, X and XI)
- CPCB, Important Notice on mandatory parameters for recognition, 10 April 2026
- CPCB, Important Notice on lab photos and videos, 8 December 2023
- CPCB, Protocol for environmental laboratories seeking recognition and portal instruction sheet
- CPCB, AQC five-year plan and notice on deposit of AQC fee for the 39th AQC exercise, 2 September 2026
- CPCB, Surprise inspection reports of recognised laboratories
- CPCB, Recognition of Labs (EP Act) page, with the list of private labs as on 24 July 2026, the list of government labs as on 31 May 2026 and the quarterly report proforma
- CPCB, Notification No. Legal/42(3)/87, 23 February 2022: schedule of sampling and analysis charges
- MoEF&CC, The Environment (Protection) Rules, 1986 (rules 9 and 10)
- MoEF&CC, Environmental labs page with recognition notifications from 2012 to 2018
- MoEF&CC, S.O. 3973(E), 29 August 2025: Environment Audit Rules, 2025, Gazette of India, Extraordinary
- PIB, Environment Audit Rules, 2025, 3 September 2025 and NPC to act as Environment Audit Designated Agency, 20 March 2026
- MoEF&CC, Guidelines for Certification and Registration of Environment Auditors through Recognition of Prior Learning for EC, CRZ, ICRZ and IPZ clearance related audits, posted 30 September 2026 (paras 7.1 and 8.1)
- MoEF&CC Expert Appraisal Committee, minutes of February 2023